PG7 Rev. A2, 07/16
12
Automation Products Group, Inc.
Advanced Settings (AdVSET):
The Advanced Settings menu is used to customize the LCD display and to
setup any optional features, such as an analog output.
Auto-Off (AUTO):
This function is applicable to battery powered units only. The Auto-O
feature allows the user to designate the time of inactivity (no buttons
pushed) until the gauge automatically powers down.
Options: 2 MIN, 4 MIN, 8 MIN, 16 MIN, 32 MIN and OFF
NOTE: Selecting OFF disables the Auto-O feature; the gauge will then
remain powered indenitely as long as there is sucient voltage being
supplied (~1.8V).
Setting the Auto-Off feature:
Step 1: Press the On/O button to enter the main setup menu.
Step 2: Press (Z) to cycle through the menu options until AdVSET is
displayed.
Step 3: Press (S) to enter the Advanced Settings menu.
Step 4: Press (Z) to cycle through the menu options until AUTO is displayed.
Step 5: Press (S) to access the Auto-O setting options.
Step 6: Press (Z) to cycle through setting options until the desired setting is
displayed.
Step 7: Press (S) to apply the setting and return to advanced setup menu.
Step 8: To exit the advanced setup menu, press (Z) until EXIT is displayed
and press (S) to exit to the main setup menu.