116
TDQ?
Read the active reactive current value being displayed while a test is in process.
TDCF?
Read the active crest factor value being displayed while a test is in process.
TDVA?
Read the active apparent power value being displayed while a test is in process.
TDTIMER?
Read the active timer meter value being displayed while a test is in process.
METER {4|3|2|1|0}
Selects the metered value that is displayed while a test is in process. 4 sets the
meter = power factor, 3 sets the meter = current, 2 sets the meter = power, 1 sets
the meter = peak current and 0 sets meter = frequency.
METER?
Read the selected meter value. Returns value of 0 4.
SDTRG
Triggers a one shot surge/drop in order to simulate loading or brown out
conditions.
STEPCYCLE?
Read the value of the current step cycle signal. When the step cycle has been
activated the query will return a value of 0 for continuous, 1 for Off or a range
from 0~9999 cycles.
MEMORYCYCLE?
Read the value of the current memory cycle signal. When the memory cycle has
been activated the query will return a value of 0 for continuous cycling, 1 for Off
or a range from 0~9999 cycles.
LOOPCYCLE?
Read the value of the current loop cycle signal. When the loop cycle has been
activated the query will return a value of 0 for continuous cycling, 1 for Off or a
range from 0~9999 cycles.

Table of Contents

Other manuals for APT 340XAC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the APT 340XAC and is the answer not in the manual?

APT 340XAC Specifications

General IconGeneral
BrandAPT
Model340XAC
CategoryAC Power Distribution
LanguageEnglish

Related product manuals