19
After the communication connection
between the inverter and the lithium
battery is successful, you can view the
information of the lithium battery
1.discharge current limited disable(default)
2. setting range :10A to 200A
setting increase or decrease of 5A .
NOTE: if you work in “Solar” or “Battery”,
when the loads is greater than the current
limiting point, it will automatically switch to
utility mode.
3.if it only works in battery mode, when
the load is greater than the current
limiting point ,the inverter will shut down
immediately.
Charge
1.Total Charge:60A(default)
Setting range is from 10A to
120A.Increment of each click is 10A.
2.AC Charge: 30A(default)
Setting range is from 2A,10A to
120A.Increment of each click is
10A.
PV
PV CAP:(Default 3k)According to the
actual capacity of the solar plate, users fill
in and set the rang of 1kva-8kva, the
increment or decrement is 0.1k per click.
Battery