EasyManua.ls Logo

Aqualisa dream - Page 22

Aqualisa dream
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
2
Feed the wall outlet thread through a 22-28mm hole in the wall
and secure with the backnut ensuring the backnut washer is fitted
between the backnut and the wall, if accessible.
3
Connect the wall outlet to a suitable ½” female connector using PTFE
tape or similar, to achieve a watertight seal.
4
Temporarily cap o the wall outlet, open the shower valve and check
for leaks.
Without rear access:
1
Run pipework from the shower valve to the desired location for the
wall outlet ensuring it terminates in a suitable ½” female connector
(not supplied). All pipework and connectors must be secured using
suitable fixings.
2
The backnut and backnut washer are not required. Wind the wall
outlet thread directly into the ½” female connector (not supplied)
using PTFE tape or similar, to achieve a watertight seal.
3
Temporarily cap o the wall outlet, open the shower valve and check
for leaks.