45 - 60
IsACQ110C-0 (ENG) Rev.230708-0
(Fig. 58)
Temperature
Insert
Programs (Fig. 58)
Allowstheusertomakeprogramsinrelationtothetempe-
rature.
Toinsertaprogram,proceedasfollows:
Main screen Main Menu Temperature Pro-
grams.
• Select the “Insert”optionwithkeys and press “En-
ter”.
Tosetupaprogram,thefollowingmustbeestablished:
- A reference value,denedasthetemperatureforthetank,
whichthesystemwillaimtomaintainbyenabling/disabling
any heaters or coolers.
- A ∆ Max value, dened as the tolerance that must be
observed with respect to values higher than the reference
value.
Forexample:Ifthereferenceissetto27°Candthe∆ Max
is0.5°C,thesystemwillbeenabledatvalues higher than
27.5°C(seechart).
- A ∆ Min value,denedasthetolerancethatmustbeob-
servedwith
respecttovalueslowerthanthereferencevalue.
Forexample:Ifthereferenceissetto27°Candthe∆ Min
is 0.3°C, the system will be enabled at values lower than
26.7°C(seechart).
NOTE: ∆ Min and ∆ Max can be the same or different.
27°C
26.7°C
27.5°C
Temperature
Time
Ref.+
∆ Max
Key to symbols
Values for which the system is enabled
∆ Max=0.5
∆ Min=0.3
Ref.
Ref.-
∆ Min
Temperature Menu