Level Menu
Insert (Fig. 79)
Inthiswindowitispossibletomodifythestateoftheplugsde-
pendingonthelevelsreadbythesensor(LEV1orLEV2).
Tosetthisprogram,proceedasfollows:
Main screen Main Menu Level Programs Insert.
Selectthestateofthesensor(OFF,LEV1,LEV2)byusing
thekeys.
Settheminimumtime(inseconds)ofprogramactivation
independently from the sensor status.
Set the maximum time (in seconds) which the output,
selectedafterwards,mustremainactive;usethekeys
tomodifythevalue.
Selectwithkeys the output which is to be utilized while
usingthekeystomodifyitsstate;itispossibletochoose
whentoactivate(outputhighlightedwithsymbolabove)or
deactivate(onlywiththesymbolabove)theoutputsincorre-
spondencetothestateofthelevelsensorselectedabove.
When completed press “Enter”tomemorizetheprogram.
Show/Modify/Delete
Seepage31.
Delete All
Seepage31.
Theexampleindicatedingure(Fig.80)showstheactivation
oftheautomatictopoffpumponplug“C”:wheneverthelevel
sensormovestothepositionLEV1,output“C”isactivated
(whichactivatestheautomatictopoffpump).
Ifthelevelsensor’sstatedoesnotchange(returnstoposition
LEV2)insidethesettime(MaxTime)theprogramisblocked
andthecontrolunitdisplaysanerrormessage.
Onthemainscreenthesymbol will appear, accompanied
by an acoustic signal; which indicates an anomaly in the
automatictopoffsystem,suchasadamagedlevelsensoror
pump,orperhapstheabsenceofwaterinthe“hopper.
Intheeventofananomaly,thefollowingmessagewillappear
(Fig.81)whichwillconsequentlyblocktheprogram.
(Fig. 79)
Programs
OFF
Minimum time 0s
Max Time: OFF
PU01 A B C D E F
(Fig. 80)
Programs
LEV 1
Minimum time 5s
Max Time: 10s
Automatic topoff pump
PU01 A B C D E F
(Fig. 81)
Sensor program
error:
Level