B. STATUS LIGHT INDICATORS & WARNINGS
1. Transmitter STATUS Light Indication
Type Display Type (Green & Red) Indication
Voltage goes below 1.9V at initial power on -
transmitter power shuts off.
1
Constant red
Voltage goes below 1.8V during operation -
transmitter power shuts off. Turn the power off
to disengage the receiver main.
2
1 red blinks followed by a 2-second
pause
Voltage goes below 1.85V during operation -
change batteries immediately.
3
2 red blinks followed by a 2-second
pause
The pushbutton is defective after turning on the
transmitter power.
4
No light displayed
When defective push button condition occurs
(2 red blinks, type 3 above), find out which push
button is defective by pressing all the push
buttons on the transmitter one at a time. If the
push button is in good working order, the LED
will not light up when pressed. If the push
button is defective the LED will continue to
display 2 red blinks when pressed.
5
3 red blinks followed by a 2-second
pause
EEPROM error.
6
4 red blinks followed by a 2-second
pause
Transmitting error, system can not locked on
to the designated channel.
7
Constant green for up to 2 seconds
Transmitter power on with no faults detected
(prior to initiating the START function).
8
Blinking green Pushbutton pressed, signal transmitted.
9
Slow red blinks
Stop command initiated with receiver
MAIN deactivated.