1.10.5 Using Sodium Chloride Test Strips. The following steps provide guidance to help ensure sodium chloride
test strips are used correctly.
Steps to Help Ensure Sodium Chloride Test Strips are Used Correctly Continued
Step 6. Sodium Chloride Adjustment
The following levels are ideal:
Minimum Maximum
2000 ppm 2500 ppm
Note: The Arctic Spas Onzen Salt Chart in this guide
provides the estimated impact of adding 1⁄2 lb (225 Grams)
of salt to your spa.
Add or dilute water as needed.
· If Sodium Chloride reading is greater than the maximum
level, add water.
· If Sodium Chloride reading is less than the minimum level,
add salt.
Note: Once Sodium Chloride reading is in the ideal range
salt concentration will only change if water is splashed or
drained out and spa is replenished with water. Do not add
salt unless this test conrms the level is below the ideal
range.
Warranty: Use of salt other than Arctic Pure sea salt blend
will damage the components and void the warranty. The
Arctic Pure blend has been developed to protect Onzen
components from damage and the use of alternative salt
blends will be easily detected by technicians.
Steps to Stabilize Water
Step 1. Stabilize Spa Water
Once Filtration cycles and ltration duration low level set-
tings have been programmed place the insulated cover
on the spa and allow the water temperature to stabilize
(approximately 16 hours). Make sure you secure the cover
in place using the cover locks. Periodically check the spa
water temperature. When the water temperature climbs
above 85°F, (29°C) proceed to the next step.
Note: As heat impacts both Calcium and Total Alkalinity a
little it is best to heat the water above 29°C (85°F) before
advancing to Establishing Correct Water Chemistry.
Filter Cycle Suspension
During a Filter cycle, if an accessory (a pump, the blower, or the light) is used manually, the Filter cycle is
suspended during the time that the accessories are used.
Once all accessories are turned o (whether manually or by built-in timer), the Filtration cycle remains
suspended for an extra 40 minutes. When a Filtration cycle is suspended the Filtration cycle icon will blink.
107107
Understanding Onzen™
Owners Manual - Onzen™