Performing Calibration
After the media loaded, it is necessary to do the calibration
for the label size detection.
1. Press and hold the pause button.
2. Turn on the power.
3. Media indicators will blink, at this point release PAUSE
button.
4. The printer will feed the labels for 6 inches.
5. Media indicators stop blinking and remain illuminated.
Note:
This procedure is very important and must always be carried out
after installation and every time the media type is changed.
Failure to do so will result in the gap and label-empty detection
being incorrect.