OPERATOR MANUAL
MANUFACTURED BY ARIBEX
Handheld X-ray System
for Intraoral Radiographic Imaging

Questions and Answers

  • J
    Jessica WilliamsSep 7, 2025
    What to do if ARIBEX Nomad Pro 2 Dental equipment X-ray image has no contrast with chemical developer?
    • B
      Bobby AvilaSep 7, 2025
      If the image from your ARIBEX Dental equipment X-ray exposure lacks sufficient contrast and you are using chemical developer, ensure that the chemical is fresh and at the correct temperature.
  • A
    Adam MclaughlinAug 22, 2025
    Why does my ARIBEX Dental equipment NOMAD Pro 2 automatically shut down?
    • J
      Jerry BrownAug 22, 2025
      If the NOMAD Pro 2 automatically shuts down during regular activity, it may require authorized service. This issue could stem from a problem other than the device timing out due to inactivity. If the shutdown occurs because the NOMAD Pro 2 times out after about three minutes of inactivity, manually turn the device back on when you are ready to use it.
  • C
    christopherrobersonSep 4, 2025
    Why image from ARIBEX Nomad Pro 2 Dental equipment X-ray has no contrast?
    • K
      Kyle GarciaSep 5, 2025
      If the image from your ARIBEX Dental equipment X-ray exposure lacks sufficient contrast due to overexposure (image is too dark), decrease the exposure time setting. Also, verify the film's expiration date, as old film may produce dark, grainy, or foggy images.
  • D
    Deborah SampsonSep 3, 2025
    What to do if there is no power to my ARIBEX Dental equipment NOMAD Pro 2 control panel?
    • L
      lewisbethanySep 3, 2025
      If there is no power to the NOMAD Pro 2 control panel of your ARIBEX Dental equipment, and pressing the power button several times doesn't illuminate the display, the attached handset is likely the problem. Ensure the handset is securely attached. If all handsets appear fully charged, the NOMAD Pro 2 will require authorized service.
  • J
    Justin AndersonSep 2, 2025
    Why does the 'Enabling X-rays' alert stay on for my ARIBEX Nomad Pro 2?
    • W
      wisejoshuaSep 2, 2025
      If the 'Enabling X-rays' alert stays on for your ARIBEX Dental equipment, it might be due to double triggering. Release the trigger and wait for the 'Ready' alert to proceed.
  • H
    huertaadamAug 31, 2025
    Why does the ready state terminate early on my ARIBEX Dental equipment?
    • B
      Brendan ChandlerSep 1, 2025
      The 'Ready' state on your ARIBEX Dental equipment might terminate early if the X-ray exposure is not initiated within 15 seconds of the start of the 'Ready' state. To prevent this, double-check the exposure time setting and re-enable when the operator and patient are properly situated.
  • B
    brownbradleyAug 30, 2025
    What should I do if my ARIBEX Dental equipment doesn't shift to the 'Ready' alert?
    • A
      Anthony HicksAug 30, 2025
      If your ARIBEX Dental equipment does not shift to the 'Enabling X-rays' alert or 'Ready' alert, it could be because the trigger is pulled for longer than one second. Try pulling and releasing the trigger within one second and then wait for the 'Ready' alert.
  • A
    angelaevansAug 29, 2025
    Why are my ARIBEX Nomad Pro 2 X-ray images blurred?
    • J
      Jeremy MartinezAug 29, 2025
      A blurred X-ray image from your ARIBEX Dental equipment is likely due to movement of the operator or patient during exposure. To fix this, check the exposure time setting and re-enable the X-rays when both the operator and patient are properly situated and still.
  • T
    Tyler HansenAug 27, 2025
    What to do if the 'Handset Failure' alarm appears on my ARIBEX Dental equipment?
    • C
      christinawalkerAug 27, 2025
      The 'Handset Failure' alarm on your ARIBEX Dental equipment indicates that the handset is not communicating with the device. First, ensure the handset is securely attached. If the issue persists, the protective fuse in the handset may be blown, or the batteries may be impaired. Replace the handset with a newly charged one. Check the charging cradle: if the charging bars illuminate solid red or not at all, the handset will require authorized service.
  • E
    Eric MartinezAug 27, 2025
    What does the 'System Failure' alarm mean on my ARIBEX Nomad Pro 2?
    • G
      gabriel65Aug 27, 2025
      The 'System Failure' alarm on your ARIBEX Dental equipment indicates that self-diagnostics detected a potential issue during X-ray firing. You can clear this warning alarm by powering the device off and then on again. If the alarm reappears, the NOMAD Pro 2 will require authorized service.

Summary

Safety Precautions

Radiation Safety

Guidelines for safe operation, operator protection, and minimizing radiation exposure.

Studies and Data on Leakage and Scatter

Presents data on radiation leakage and scatter, comparing NOMAD Pro 2 exposure levels to limits.

Setup and Power Check

The Backscatter Shield

Describes the function and adjustment of the backscatter shield for operator protection.

Operation

Ensuring the Right Exposure Time is Set

How to select and set appropriate exposure times based on patient and imaging parameters.

Initiating and Completing an X-ray Exposure

Detailed process for starting and finishing an X-ray exposure using the trigger.

Exposure Techniques

Guidance on positioning the device and patient for optimal intra-oral X-ray imaging.

Ensuring Image Quality

Features contributing to image quality and tips for achieving optimal results.

Technique Factors Settings and Adjustments

Provides pre-set technique factors and guidance for adjusting them based on patient needs.

NOMAD Pro 2 Care and Upkeep

Troubleshooting

A guide to diagnosing and resolving common operational problems and error messages.

ARIBEX Nomad Pro 2 Specifications

General IconGeneral
TypeHandheld X-ray System
Tube Voltage60 kV
Tube Current2.5 mA
Focal Spot0.4 mm
Total Filtration1.5 mm Al equivalent
DisplayLCD
UsageIntraoral Radiography
X-ray GeneratorHigh Frequency
X-ray SourceX-ray tube
Weight2.5 kg (5.5 lbs)
Battery TypeLithium Polymer
Image SensorNot applicable (external sensor required)
Battery LifeUp to 400 exposures per charge

Related product manuals