84 / GB
MENU
SUB-MENU
PARAMETER
DESCRIPTION
RANGE DEFAULT
17 1 0 HV Input 1
Not Dened
Absent
EDF
SG1
External switch o signal
Absent
17 1 1 HV Input 2
Not Dened
Absent
DLSG
SG2
External switch o signal
Absent
17 1 2 HV Input 3
Not active
PV Integration Active
Not active
17 1 3 AUX Input 1
None
Humidistat sensor
None
17 1 4 AUX Output 1 (AFR)
None
Fault alarm
Humidistat alarm
External heat request
Cooling request
None
17 1 5 AUX Output 2
None
Fault alarm
Humidistat alarm
External heat request
None
17 1 6 AUX P2 circulator setting
Auxiliary circulator
Cooling circulator
Buer circulator
Auxiliary circulator
17 2 Energy manager parameter 1
17 2 0 Hydraulic scheme
None
Plus
Compact
Flex
Hp Water Heater
Light (NOT USED)
None
17 2 1 Thermoregulation
Absent
Present
Present
17 2 2 ECO / COMFORT
Eco Plus
Eco
Average
Comfort
Comfort Plus
Average
17 2 3 FlowT HP Oset 0 ÷10°C 2°C
17 2 4 Boost Time 0 ÷ 60 min 16 min.
17 2 5 External temperature correction - 3; + 3°C 0°C
17 2 6 Active Resistance Stages
1 Stage
2 Stages
3 Stages
2 Stages
17 2 7 Pro-Tech anode active OFF - ON OFF
17 2 9 Antiblocking pump enable OFF - ON ON
17 3 Central Heating
17 3 0 CH pump prerun time 30 ÷ 255 sec. 30 sec.
17 3 1 Time for prerun new attempt 0 ÷ 100 sec. 90 sec.
17 3 2 CH Pump Overrun 0 ÷ 16 min. 3 min.
17 3 3 Pump Speed Control
Low speed
High speed
Modulating
Modulating
17 3 4 Delta T Pump Setpoint 5 ÷ 20°C 5°C
17 3 5 Min Pressure 0,3 ÷ 0,4 bar 0,4 bar
17 3 6 Warning Pressure 0,4 ÷ 0,8 bar 0,6 bar
17 3 7 Max PWM Pump min PWM ÷ 100% 100%
17 3 8 Min PWM Pump 20% ÷ max PWM 40%