86 / GB
MENU
SUB-MENU
PARAMETER
DESCRIPTION
RANGE DEFAULT
17 8 3 Floor drying functional Remaining Days only read
17 8 4 Floor drying curing Remaining Days only read
17 8 5 Refrigerant Recover OFF - ON OFF
17 8 6 Resistance Power Rating Conguration
2+2(+2) kW
2+4 kW
OFF
17 8 7 Defrost OFF - ON OFF
17 8 8 TDM Flow Sensor Type
Not Selected (Self-Recognition)
DN 15
DN 20
Not Selected
17 9 Energy Manager Statistics
17 9 0 HP Running hours (h/10) only read
17 9 1 HP On cycles (n/10) only read
17 9 2 Resistor Stage 1 running hours (h/10) only read
17 9 3 Resistor Stage 2 running hours (h/10) only read
17 9 4 Resistor Stage 3 running hours (h/10) only read
17 9 5 Resistor Stage 1 On cycles (n/10) only read
17 9 6 HP Defrost hours (h/10) only read
17 9 7 Cooling running hours (h/10) only read
17 9 8 Heating running hours (h/10) only read
17 9 9 DHW running hours (h/10) only read
17 10 HP Diagnostics - 1
17 10 0 Outside air temperature only read (°C)
17 10 1 HP water ow temp only read (°C)
17 10 2 HP water return temp only read (°C)
17 10 3 HP Evaporator temp only read (°C)
17 10 4 HP Suction temp only read (°C)
17 10 5 HP Discharge temp only read (°C)
17 10 6 HP condenser outlet temp only read (°C)
17 10 7 TEO only read (°C)
17 11 HP Diagnostics - 2
17 11 0 Heat Pump Mode
OFF
Stand by
Cooling
Heating
Booster Heating
Booster Cooling
Rating in Heat Mode
Rating in Cooling Mode
Freeze Protection
Defrost
High Temperature Protection
Timeguard
System Fail
Hard System Fail
Pump Down
only read
17 11 1 HP Error 0 ÷ 29 only read
17 11 3 Flowmeter 0 ÷ 1200 l/min only read (l/min)
17 11 4 Flow Switch Open - Closed only read
17 11 5 Inverter shut o protection OFF - ON only read
17 11 6 PEVAP - Evaporator Pressure P only read
17 11 7 PCOND - Condenser Pressure P only read
17 11 8 Last inverter error only read
17 12 HP Diagnostics - 3