On: listen-in only mode: this allows the central station to listen to the activity
at the premises.
Off: normal two-way mode: this allows the central station to communicate
with the person(s) at the premises. The procedure is controlled from the
central station by using keypresses on a touch tone telephone.
3
Speaker Lockout (default = Off)
Off: the Automatic Speaker Lockout is enabled.
On: the Speaker Lockout is disabled.
4
Microphone-A start-up selection (default = on )
Enabling this feature will turn on microphone-A at start-up.
5
Microphone-B start-up selection (default = on )
Enabling this feature will turn on microphone-B at start-up.
6
Call in feature answering machine defeat enabled (default = off )
When a call-in is made, at least one ring must be received. The line is
picked up and the CS534 listens for a master code to be entered within the
30-second time limit. If the answering machine defeat is enabled, the code
must be entered even if someone answers the phone. If this feature is not
enabled, the CS534 waits for the number of rings programmed in location 4,
segment 4. Call-in must be enabled in location 4, segment 4.
7 -8
This feature enables Level 7 – Status Check and Level 8 –
Arming/Disarming Partition 1. The factory default for this segment is off.
Location 1 Call back access code (default = 123456) (six segments, ND)
This location contains the access code used to start a listen-in session when the CS534 is
in call back mode. The call back access code can be up to a maximum of six digits. The
valid entries are 0 to 15 (10 = , 11 = #, 12 = none, 13 to 15 = any digit). If less than six
digits are desired, program a 15 at the end of the desired code. If segment 1 contains a
15, any digit accesses the CS534. If segment 1 is a 12, no access code is required.
Location 2 Line hold mode access digit (default = 15(F) (one segment, ND)
This digit is required to start a two-way session if line-hold mode is used. Valid entries are
0 to 15 (10 = , 11 = #, 12 = none, 13 to 15 = any digit). If segment 1 is a 12, no access
digit is required. If it is programmed as a 15, any digit accesses the CS534.
Location 3 Timing options (8 segments, ND)
Seg 1
Line hold timeout (Default = 60 seconds)
Determines how long the CS534 waits for the line-hold digit programmed in
location 2 while in the line-hold mode. When a digit is pressed, the timer is
reset. If the digit is not received during this time, the CS534 hangs-up
(disconnects). This time is programmable from 10 to 255 seconds for each
digit.
Seg 2
New trip hangup time (Default = 20 seconds)
Determines where the CS534 sets the session timer when a new trip is
received on the same partition during a two-way session. This time is
programmed from 1 to 255 seconds and is extended if there is any activity
from the central station. If an alarm occurs in the same partition, pressing a
key in this time period extends the session timer. If the alarm is in a different
partition, the timer is reduced automatically and allows the timer to be
restarted.