1.1.2 Specifications
Main technical and operational characteristics of DIS-IP2 are given in Table 2.
Table 2 - Main technical and operational characteristics of DIS-IP2
Parameter Value
Power supply through PoE line (IEEE 802.3af/ IEEE 802.3at), V
-48
External DC power supply, V
12 or 48
Maximum consumption current through PoE line, maximum, А
0,3
Maximum consumption current at 48 V, maximum, А
0,3
Maximum consumption current at 12 V, maximum, А
1,2
LF-signal bandwidth (at -3 dB level)*, Hz
From 300 to 6800
Maximum electrical power of built-in two-channel amplifier per each chan-
nel, minimum, W
1,0
Communication interface**
100BaseT Ethernet
Communication protocols via Ethernet interface
SIP, Armtel-IP,
SNMP
Communication interface*
ADSL, ADSL2,
ADSL2+
Communication protocols via ADSL line
IEEE802.3,
IEEE802.3u, ITU
G.992.1…992.5
Communication interface
WI-FI 2.4
Communication protocols via Wi-Fi
IEEE 802.11a/b/g/n
Electrical protection class (under GOST IEC 61140-2012)
III
Protection degree
IP40
Air temperature range, ºC
From - 5 to + 55
Relative air humidity at +25 ˚С, %
Up to 80
The total duration of sound fragments recorded in the device's memory, mini-
mum, minutes
1500
Overall dimensions, maximum, mm (with fully turned up microphone)
285×200×416