Protocol
50
Mode 2: CCT, 8 bit Resolution per Function
Mode 3: CCT & HSI, 8 bit Resolution per Function
10-12 Reserved (only V4.x)
Channel Value Percent Function
1
0-255 0-100
Dimmer
closed open
2
0-255 0-100
Color temperature CCT
2.800 K 10.000 K
3
0-10
11-20
21-119
120-145
146-244
245-255
0-4
5-8
8-46
47-57
57-96
96-100
GN saturation
neutral / no effect
full minus green
-99% -1%
neutral / no effect
1% 99%
full plus green
4
Reverts to
fixture set-
ting when
signal lost.
0-9
10-60
61-120
121-180
181-250
251-255
0-4
5-23
24-47
48-70
71-98
99-100
Fan Control
No function
Low
Variable
High
Fan max. speed
Fan off
5-7 Reserved (only V4.x)
Channel Value Percent Function
Channel Value Percent Function
1
0-255 0-100
Dimmer
closed open
2
0-255 0-100
Color temperature CCT
2.800 K 10.000 K
3
0-10
11-20
21-119
120-145
146-244
245-255
0-4
5-8
8-46
47-57
57-96
96-100
GN saturation
neutral / no effect
full minus green
-99% -1%
neutral / no effect
1% 99%
full plus green
4
0-255 0-100
Xfade to color
white RGBW color
5
0-255 0-100
Hue
360°
6
0-255 0-100
Saturation
0 full saturated
7
Reverts to
fixture set-
ting when
signal lost.
0-9
10-60
61-120
121-180
181-250
251-255
0-4
5-23
24-47
48-70
71-98
99-100
Fan Control
No function
Low
Variable
High
Fan max. speed
Fan off
8-10 Reserved (only V4.x)