EasyManua.ls Logo

Arrow eSTOP - Estop System Specifications

Arrow eSTOP
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
eSTOP Operations & Service Manual
Arrow Emergency Systems | 17 Bailey Court Brendale Q 4500 | P: (07) 3881 3302 | www.arrowes.com.au
Page |
7
eSTOP System Specifications
eSTOP™ Unit
Operating life of cluster: 100,000 hours
View angel of cluster: 12
Lantern IP rating: IP45
LED Optics IP rating: IP65
Voltage: 12v
Operating amperage: 1.2 A
Battery (rechargeable) 21 A/H Lithium Iron phosphate
Operating Hours (80% DoD) ~16 Hours
Charging time: 4-5 Hours
Operating Temperature Range: -20 to 90 Celsius
Lantern Compliancy AS2144
Hand Remote Controller (HRC)
RF operating frequency: 2.4GHz
Configuration: Single unit or dual unit control
IP rating: IP45
Weight: 300g
Battery (rechargeable): 6.5 A/H Lithium Polymer
Operating Hours (25% DoD) ~13 Hours
Charging time: ~3 Hours
Operating Current: (Transmitting) 120mA
Sleeping Current: 1mA
Operating Temperature Range: -20 to 85 Celsius
Overall Device
Total mass per device (incl. batt, Target Board): 24kg (allocated to 3 components)
Top lantern weight (max lifting weight): 14kg
Tripod leg footprint radius: 0.80m
Tripod Load Rating: 500 Kg
Wind loading no sandbag base: ~40km/h
Wind loading 3 sandbag/leg ~50kg: ~100km/h
Dimensions
Maximum working height: 2900 cm
Minimum working height: 2600 cm
Dimensions when stored: 1710 mm x 480mm x 370mm
Base width, fully extended: 1600 mm diameter
Lantern height: 770 mm
Lantern width: 270 mm
Lantern depth: 170 mm