Charging Rack Installation
INSTALLATION AND OPERATION MANUAL
CR3 CR5, and CR7 Charging Racks
2 Charging Rack Installation
2.1 General
The unit shall be installed by authorized personnel only.
• The units shall be placed in a dry environment with a temperature range from +5° C up to + 40° C (41° F to
104° F).
• The units shall be mounted on a vertical wall.
• Avoid mounting the Charging Rack in a sunlit place. This can affect the charging capacity.
• Avoid mounting the Charging Rack where radio/network coverage is not sufficient. This can reduce the
messaging capacity.
• The unit can be mounted to a vertical wall (concrete or plaster walls only) no higher than 2000 mm or be
placed on table if table adapters are used.
• If the Charging Rack is connected to a power supply via an AC wall plug, serial power supply connection
is not allowed.
• If the Charging Rack is connected to a power supply via an AC wall plug, the socket-outlet shall be
situated near the equipment and shall be easily accessible.
• If the Charging Rack is connected to a power supply via a fixed connection, a readily accessible
disconnect device shall be incorporated in the building installation wiring.
Delivery Includes
• Charging Rack
• Power supply cord including IEC C14 connector (male)
• Inlet accessory kit including cable support holders and screws
• Table adapters
An extension cord IEC C13 AC connector (female, IEC60320-C13) to wall socket has to be ordered
separately. It shall be connected between the pre-installed IEC C14 AC connector (male) and the
wall socket.
Required Tools etc.
• Screwdrivers
• Cutting pliers
• Multimeter
• Screws and wall plugs for wall mounting.
Make sure the screws and wall plugs have the correct length for the type of wall used.
5 TD 92480EN / 30 October 2020 / Ver. L