Main Menu (Continued)
Auto Memory
The Auto Memory feature is used to automatically store the reading in the memory
and reset the display to 0. The user does not need to press RESET key or MEM
key. When you get the peak value, the reading will automatically be stored in
the memory included the torque reading, unit, date, and time. If you activate this
feature, the AM symbol will be displayed on the main display.
• To access the Auto Memory menu, press and hold the MENU key to access the
main menu. Use the UP or DOWN arrow keys to move the cursor to SETTING
and press ENTER. Use the UP or DOWN arrow keys to move the cursor to AUTO
MEMORY and press ENTER.
• If OFF is selected in this mode, the auto memory feature will be turned off
• If CLOCKWISE is selected in this mode, tester will only record the clockwise
torque reading. If counter-clockwise torque is applied, the tester will reset the
reading and the tester will be ready to take new reading.
• If COUNTER-CLOCKWISE is selected in this mode, the tester will only record
counter-clockwise torque reading. If clockwise torque is applied, the tester
will reset the reading and the tester will be ready to take new reading.
DTT Series Digital Torque Testers
User Manual
Auto Print
The Auto Print feature is used to automatically send measured value to ports
connection. The user does not need to press the PRINT key. When you receive the
measured value will automatically send to ports connection. If you activate this
feature, the AP symbol will display on the main display.
• To access the Auto Print menu, press and hold the MENU key to access the main
menu. Use the UP or DOWN arrow keys to move the cursor to SETTING and
press ENTER. Use the UP or DOWN arrow keys to move the cursor to AUTO
PRINT and press ENTER.
• If OFF is selected in this mode, turns auto print feature off
• If CLOCKWISE is selected in this mode, the auto print feature will work in
specic clockwise direction only
• If COUNTER-CLOCKWISE is selected in this mode, the auto print feature will
work in specic counter-clockwise direction only