13
4
3
2
1
REHANGING OF DOOR
1 Detach the two screws holding the outer
roof. The screws are located beneath
the blind plugs (1). as illustrated, and
remove the roof.
2 Remove the protective cover (2) on the
upper hinge and separate the door cable
(3) from the connector (4). Thread the
cable through the hole in the chassis
and stretch out the cable.
3 Remove the upper hinge and release
the cable from the hinge. The hinge has
a slot through which the cable can be
threaded. See illustration.
Release the door from the hinge and to-
gether with the control cable lay it aside.
4 Fit the new replacement hinge, which
is included in the rehanging kit, on the
opposite side. Use the same screws as
previously.
The pictures below illustrate rehanging from right-hung door to left-hung.
Rehanging kit
For rehanging, a rehanging kit must be ordered from the supplier of the cabinet. The
kit consists of a new upper hinge, as the left and right hinges are not interchange-
able. The kit also includes a control cable for tting in the door with associated
hinge bushing.
Lay the cabinet down carefully on
its back.
_______________________________
NB
Before placing the cabinet on its back, take
out and empty the water tank.
_______________________________________
Upper hinge with slot