Service manual WM70
37
Fault indications WM70.3
4HE BELOW FAULTS ARE INDICATED IN PLAINTEXT IN ,#$ 4HE TABLE SHOWS THE INDICATION IN ALL LANGUAGES AND LANGUAGE VARIATIONS
,#$ Cause Action
Over flow fault, Overflow Fault, Over
flow fault, Överfyllnad, Overløbsfejl,
Overflom, Ylitulviminen, Trop plein,
Überfüllt, Troppo pieno, Desborde,
Пeрeл и в вoды, Te veel water
Too much water in the machine Service action:
#HECK THE MACHINES LEVEL SYSTEM INLET VALVE AND DRAIN PUMP
Make sure that there is no leaks.
The drain pump is on, without any
water in the machine.
Service action:
The overflow protection at the bottom of the machine is
activated (not all models). Make sure that there is no leaks
(water on the machines base)
Water outlet fault, Water
Outlet Fault, Water outlet fault,
Uttömningsfel, Udpumpningsfejl,
Vannutløp, Vedenpoistovika, Défaut ,
Wasserablauffehler, Uscita acqua, Fallo,
Слив вoды, Waterafvoer fout
1. The drain pump has been
activated more than 3 minutes.
There is still water in the machine.
2. The wash cycle is interrupted
and the program is cleared
Customer information:
1. Check that no objects are stuck in the drainage hose
outlet.
2. Check that the drain pump is not blocked by foreign
objects.
3. Check that there are no kinks in the drainage hose.
Service action:
1 .If the pump only runs for a short while (approximately 20
seconds), this indicates a fault in the level system. Check the
level sensor and hoses.
2. Check wiring and voltage to the pump. If necessary, replace
the pump and/or control
3. After implementing corrective action, run the Drain
program or press the Key button
Water inlet fault, Water Inlet Fault,
Water inlet fault, Vattenintagsfel,
Vandindtagsfejl, Vanntilførsel, Vika
vedenotossa, Défaut,
Wasseraufn.-fehler, Entrata acqua , Fallo
, Haбoр вoды, Watertoevoer fout
If the correct water level is not
reached within 5 minutes, the
wash cycle is interrupted.
Customer information:
1. Check that the tap on the water pipe is open.
Service action:
#HECK THAT THE lLTER IN THE MACHINES WATER INTAKE IS NOT BLOCKED
2. Check the inlet valve. If necessary, replace the valve.
3. Check voltage to the inlet valve. If there is no voltage, this
could be due to a fault in the level system, wiring or control unit.
Security fault, Security Sys Fault,
3ECURITY FAULT ,UCKPPNINGSFEL
Sikkerhedsfejl, Sikkerhetsfeil, Vika
turvajärj., Erreur sécurité, Sicherh.-
fehler, Err. sis.sicurezza, Fallo sistema
seguridad, Oшибкa сис.бeзoп.,
Deurslot fout
The door is open. Close the door
Thermistor fault, Thermistor Fault,
Thermistor fault, Termistorfel,
Termostat fejl, Termistor,
Termistorivika, Défaut , Termistorfehler,
Termistore , Fallo , Teр мис тoр, Temp.
sensor fout
1. The circuit for the thermistor
is open.
2. The thermistor is faulty
3. The measurment value for the
thermistor is <300 : (>120 °C )
Service action:
Check the thermistors function. If needed, replace it.
Temperature fault, Temperature Fault ,
Temperature fault, Temperaturstoppfel,
Temperatur fejl, Temperaturstopp,
Ei lämmitä vettä, Défaut , Temp.-
stoppfehler, Errore arresto , Fallo ,
Teмпe рaт урa, Temperatuurstop
s 4HE TEMPERATURE IS RAISED
°C/41°F within 10 minutes. The
wash cycle continues to next step
Service action:
Check the heater, cables, thermistor and level system.
Wash motor fault, Wash Motor Fault
, Wash motor fault, Motorfel, Motor
fejl, Motorfeil, Moottorivika, Défaut ,
Motorfehler, Motore lavaggio , Fallo ,
Moтoр, Motorstoring
.O SIGNAL FROM 4ACHO OR -#5 Service action:
Check signal from the MCU and cables between motor and
MCU.
Pressure fault, Pres Sensor Fault,
Pressure fault, Trycksensorfel,
4R YKSENSOR FEJL .IVËFEIL
Painesensorivika, Défaut ,
Drucksensorfehler, Pressostato , Fallo ,
Дaтчик урoвня, Druksensor fout
Indicated if the level drops to
0 within 30 seconds of the first
rinsing.
Service action:
Check the leakage
Unbalance, Unbalance, Unbalance, Obalans,
Ubalance, Ubalance, Epätasapaino, Balourd,
5NWUCHT .ON BILANCIATO $ESEQUILIBRIO
Дисбaлaнс, Onbalans
After 10 failed attempets to
spin the load the machine has
stoped to spin beacuse of to high
umbalance.
Information to customer:
- Small loads with heavy items can cause this problem when
these articles are difficult to redistribute.
!FTER CARRYING OUT CORRECTIVE ACTIONS AS ABOVE RESET THE FAULT INDICATIONS BY PRESSING THE $//2 /0%2).'
"544/. AT THE SAME TIME AS THE MAIN POWER SWITCH