February 2012 16 80-0180-262 Rev. D
SET EMERGENCY HOLD-OPEN (UNLOCK)
TIME (THIS NUMBER CAN BE BETWEEN 1 AND 9 SECONDS. DE-
FAULT IS 10 SECONDS)
Depress and hold # key (approximately 5 seconds).
Release when yellow LED blinks. (Yellow LED will blink continuously
during programming)
Enter Master or Supervisor Code # (Green flash with 2 short tones)
Enter 46 # (Green flash with 2 short tones)
Enter 1 through 9 # (Green flash with 2 short tones)
Green flash with 2 short tones will repeat to indicate successful setting.
Press # within 2 seconds to stay in programming mode. The following
Options and Settings require different PCC Codes.
80-0180-262 Rev. D 13 February 2012
DELETE ALL USER CODES (RETURN TO FAC-
TORY DEFAULT)
Depress and hold # key (approximately 5 seconds).
Release when yellow LED blinks. (Yellow LED will blink continuously
during programming)
Enter Master or Supervisor Code # (Green flash with 2 short tones)
Enter 60 # (Green flash with 2 short tones)
Re-Enter 60 # (Green flash with 2 short tones)
Green flash with 2 short tones will repeat to indicate successful code
programming.
Note: Supervisor Code will delete locations 6-150.
DELETE SUPERVISOR, LOCKOUT, PASSAGE,
OR A SINGLE NORMAL USER CODE
Depress and hold # key (approximately 5 seconds).
Release when yellow LED blinks. (Yellow LED will blink continuously
during programming)
Enter Master Code # (Green flash with 2 short tones)
Enter 61 # (Green flash with 2 short tones)
Enter Code Location # (Green flash with 2 short tones)
Green flash with 2 short tones will repeat to indicate successful code
programming.
Note: Supervisor Code will delete locations 4-150.
DELETE A BLOCK OF NORMAL USER CODES
Depress and hold # key (approximately 5 seconds).
Release when yellow LED blinks. (Yellow LED will blink continuously
during programming)
Enter Master or Supervisor Code # (Green flash with 2 short tones)
Enter 62 # (Green flash with 2 short tones)
Enter First Location (of block to be deleted) # (Green flash with 2 short
tones)
Enter Last Location (of block to be deleted) # (Green flash with 2 short
tones)
Green flash with 2 short tones will repeat to indicate successful code
programming.
Press # within 2 seconds to stay in programming mode. The following
Options and Settings require different PCC Codes
Note: Master Code will delete locations 3-150.