February 2012 14 80-0180-262 Rev. D
RESET ALL FEATURES (NOT INCLUDING CODES) TO
DEFAULT VALUES
Depress and hold # key (approximately 5 seconds).
Release when yellow LED blinks. (Yellow LED will blink continuously
during programming)
Enter Master or Supervisor Code # (Green flash with 2 short tones)
Enter 72 # (Green flash with 2 short tones)
Enter 72 # (Green flash with 2 short tones)
Green flash with 2 short tones will repeat to indicate successful reset to
default.
Press # within 2 seconds to stay in programming mode. The following
Options and Settings require different PCC Codes.
SET AUDIBLE KEYPAD FEEDBACK
(DEFAULT IS ENABLED).
Depress and hold # key (approximately 5 seconds).
Release when yellow LED blinks. (Yellow LED will blink continuously
during programming)
Enter Master or Supervisor Code # (Green flash with 2 short tones)
Enter 31 # (Green flash with 2 short tones)
Enter 1 # to Enable (Green flash with 2 short tones)
or Enter 0 # to Disable (Green flash with 2 short tones)
Green flash with 2 short tones will repeat to indicate successful setting.
Press # within 2 seconds to stay in programming mode. The following
Options and Settings require different PCC Codes.
SET VISUAL KEYPAD FEEDBACK (DEFAULT IS ENABLED).
Depress and hold # key (approximately 5 seconds).
Release when yellow LED blinks. (Yellow LED will blink continuously
during programming)
Enter Master or Supervisor Code # (Green flash with 2 short tones)
Enter 32 # (Green flash with 2 short tones)
Enter 1 # to Enable (Green flash with 2 short tones)
or Enter 0 # to Disable (Green flash with 2 short tones)
Green flash with 2 short tones will repeat to indicate successful setting.
Press # within 2 seconds to stay in programming mode. The following
Options and Settings require different PCC Codes.
80-0180-262 Rev. D 15 February 2012
SET NUMBER OF SUCCESSIVE INVAILD
USER CODE ENTRIES ACCEPTED (THIS NUMBER
CAN BE BETWEEN 1 AND 255 ATTEMPTS. DEFAULT IS 5)
Depress and hold # key (approximately 5 seconds).
Release when yellow LED blinks. (Yellow LED will blink continuously
during programming)
Enter Master or Supervisor Code # (Green flash with 2 short tones)
Enter 33 # (Green flash with 2 short tones)
Enter 1 to 255 # (Green flash with 2 short tones)
Green flash with 2 short tones will repeat to indicate successful setting.
Press # within 2 seconds to stay in programming mode. The following
Options and Settings require different PCC Codes.
SET THE ERROR LOCKOUT TIME (THIS IS THE
AMOUNT OF TIME THE USER IS UNABLE TO USE THE KEYPAD
FOLLOWING SUCCESSIVE INVALID ATTEMPTS. THIS NUMBER CAN
BE BETWEEN 1 AND 255 SECONDS. DEFAULT IS 15 SECONDS)
Depress and hold # key (approximately 5 seconds).
Release when yellow LED blinks. (Yellow LED will blink continuously
during programming)
Enter Master or Supervisor Code # (Green flash with 2 short tones)
Enter 34 # (Green flash with 2 short tones)
Enter 1 to 255 # (Green flash with 2 short tones)
Green flash with 2 short tones will repeat to indicate successful setting.
Press # within 2 seconds to stay in programming mode. The following
Options and Settings require different PCC Codes.
SET THE HOLD-OPEN (UNLOCK) TIME (THIS IS
THE AMOUNT OF TIME THE eFORCE 150 WILL REMAIN UNLOCKED
FOLLOWING A SUCCESSFUL USER CODE ENTRY. THIS NUMBER CAN
BE BETWEEN 1 AND 9 SECONDS. DEFAULT IS 5 SECONDS)
Depress and hold # key (approximately 5 seconds).
Release when yellow LED blinks. (Yellow LED will blink continuously
during programming)
Enter Master or Supervisor Code # (Green flash with 2 short tones)
Enter 44 # (Green flash with 2 short tones)
Enter 1 to 9 # (Green flash with 2 short tones)
Green flash with 2 short tones will repeat to indicate successful setting.
Press # within 2 seconds to stay in programming mode. The following