Copyright © 2020-2021, ASSA ABLOY Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Inc. is prohibited.
15
Part Description Configuration
Set Screw Pins (
1
/
4
"-20) All
2x Cup Point Set Screw (
1
/
4
"-20 x
5
/
16
") for Post Base Section All
Deco End Cap (threads) All
FHSCS (
1
/
4
"-20) for Actuator Post All
FHSCS (6-32) for Latch Assembly All
2x SHCS (
5
/
16
"-18) for Manual Strike All Single Manual Strike
3x SHCS (
5
/
16
"-18) for Double Manual Strike All Double Manual Strike
2x SHCS (
5
/
16
"-18) for Electric Strike All Single Electric Strike
4x SHCS (
5
/
16
"-18) for Double Electric Strike All Double Electric Strike
• CAUTION: Make sure the following maintenance steps are completed before operating the Panic Device.
• Refer to the appropriate sections of this Panic Device manual for Threadlocker and Lube applications and their locations.
4.3 Mechanical Maintenance
Threadlocker is applied to the following parts
Part Description Configuration
Post Base Section All
Latch All
Lubricant is applied to the following parts
• Periodically, re-lubricate the above components of the device.
Thread Type Torque Requirement - in-lbs (N-m)
6-32 9.6 in-lb (1 N-m)
8-32 19.8 in-lb (2.5 N-m)
12-24 55 in-lb (6 N-m)
1
/
4
-20 75.2 in-lb (9 N-m)
5
/
16
-18 132 in-lb (16 N-m)
Torque Values for different Thread Types