Service/Maintenance
Service and adjustments performed by your ASSA ABLOY Entrance Systems-authorized representative
will ensure safe and proper operation of your automatic door unit.
Remember to keep “Service Log Book” and “Site Acceptance Test and Risk Assessment” documents
(PRA-0007) available. These are used together.
The table below shows the recommended interval in months, when to replace parts during preventive
maintenance. Talk to your ASSA ABLOY Entrance Systems representative to learn more about our
service offering.
Abusive
Environ-
ment
Cycles/hour in operationPart numberPart
>100<100<10
High
traffic
Medium
traffic
Low
traffic
661224330000271BK/SIPUSH arm service kit
661224330000272BK/SIPULL arm service kit
661224330000276Stop arm kit
661224330000275Micro switch kit
661224330000270BK/SIAdaptor kit
60606060331007291Transmission unit
60606060331007504Connection box kit
60606060331008346Control unit CU-200 with
EXU-boards
Other products from ASSA ABLOY Entrance Systems
• Vertical lifting fabric doors• Door Systems
• Dock levelers• Balance doors
• Dock shelters• Air curtains
• Folding doors• Revolving doors
• High speed doors• Sliding doors
• Loadhouses• Automatic and manual activation units
• Overhead sectional doors
• Service such as preventive maintenance and upgrade programs, emergency repairs, service
advice and door management