Service/Maintenance
Service and adjustments performed by your ASSA ABLOY Entrance Systems-authorized representative
will ensure safe and proper operation of your automatic door unit.
Remember to keep Service Log Book and Site Acceptance Test and Risk Assessment documents
(PRA-0007) available. These are used together.
The table below shows the recommended interval in months, when to replace parts during preventive
maintenance. Talk to your ASSA ABLOY Entrance Systems representative to learn more about our
service offering.
Abusive
Environ-
ment
Cycles/hour in operationPart numberPart
>100<100<10
High
traffic
Medium
traffic
Low
traffic
661224330000271BK/SIPUSH arm service kit
661224330000272BK/SIPULL arm service kit
661224330000276Stop arm kit
661224330000275Micro switch kit
661224330000270BK/SIAdaptor kit
60606060331007291Transmission unit
60606060331007504Connection box kit
60606060331008346Control unit CU-200 with
EXU-boards
Other products from ASSA ABLOY Entrance Systems
Vertical lifting fabric doors Door Systems
Dock levelers Balance doors
Dock shelters Air curtains
Folding doors Revolving doors
High speed doors Sliding doors
Loadhouses Automatic and manual activation units
Overhead sectional doors
Service such as preventive maintenance and upgrade programs, emergency repairs, service
advice and door management