Regular safety checks
To help you fulfil the national/international requirements and to avoid malfunction and risk for injuries,
we have provided the following checklist.
Do not use if repair or adjustment is necessary.
If problem oc-
curs
Daily Action
Activate your operator and check visually, fastening and any damage of
operator
1
arm system
2
position switch
3
hinges
4
door and glass
5
Also inspect your operator and check visually for
sharp edges on the door leaf and door frame (if any)
6
condition of door seals
7
finger protection
8
pivot
13
and finally that the complete door runs properly and closes slowly in a smooth way
Set the programme selector in OFF mode and check that the operator and lock work together. Also check
that the lock really secures the door
9
.
Activate the manual activation units
10
if any, and walk towards the door. Check that the door has opened
sufficiently while you pass the entrance/exit.
Then proceed with the automatic activation units
11
in the same way.
Check the non-monitored safety sensors
12
if any, by standing in the swing path and activate the operator.
The door must not hit you when opening nor when closing. If you are unsure of which type of sensor you
have, please contact your ASSA ABLOY representative.
Set the programme selector in AUTO mode. Push the door manually in es-
cape direction and make sure that no object or function will prevent the
door from opening. Also make sure the escape route is free for use.
By law, these tests must be performed regularly
by trained personnel.
Escape
doors
Let the door close after an impulse and make sure thatnoobjectwillprevent
the door from closing and locking (if demanded).
Fire doors
See page 10 for more information about safety checks.
Contact your ASSA ABLOY representative. For contact information, see last page.=
Take appropriate measures.=
1007717-en-US-3.0Issue 2018-03-288

Other manuals for Assa Abloy SW200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Assa Abloy SW200 and is the answer not in the manual?

Assa Abloy SW200 Specifications

General IconGeneral
Protection RatingIP20
Power Supply230 VAC, 50/60 Hz
Operating Temperature-20°C to +50°C
ControlMicroprocessor control
SafetyObstacle detection
ComplianceEN 16005
Ambient Temperature-15°C to +50°C
Relative HumidityUp to 95% non-condensing
Opening SpeedAdjustable
Closing SpeedAdjustable
Hold-open TimeAdjustable, 0-30 seconds
Dimensions100 mm

Related product manuals