DRV-24 frequency inverters Product Overview
8
Function
Specification
interface
Analog output
2 (AO1, AO2*) 0~10V/0~20mA
* AO2 for devices with power input ≥4kW
Digital input
4 common inputs, the Max. frequency: 1kHz;
1 high speed input, the Max. frequency:
50kHz
Digital output
1 Y1 terminal output
Relay output
2 programmable relay outputs
RO1A NO, RO1B NC, RO1C common terminal
*RO2A NO, RO2B NC, RO2C common terminal
Contact capacity: 3A/AC250V
* for devices with power input ≥4kW
Others
Temperature of the
running
environment
-10~50°C, derate 1% for every additional 1
when above 40
DC reactor
Standard embedded DC reactor for the
inverters (≥18.5kW)
Installation mode
Wall and rail installation of the
inverters(single phase 220V/three phase
380V, ≤2.2KW)
Wall and flange installation of the
inverters(three phase 380V, ≥4KW)
Braking unit
Standard for the inverters37kW and optional
for the inverters of 45~110kW
Protective degree
IP20
Note: The inverter with plastic casing should
be installed in metal distribution cabinet,
which conforms to IP20 and of which the top
conforms to IP3X.
Cooling
Air-cooling
EMI filter
Embedded C3 filters for the inverters(three
phase 380V, 4kW and three phase 220V,
1.5kW) ; external C2 filter is optional for all
series;
Optional filter: meet the degree requirement
of IEC61800-3 C2, IEC61800-3 C3
Safety
Meet the requirement of CE