Astraada DRV-24 frequency inverters Function Parameters
55
Detailed instruction of parameters
password is incorrect, users cannot enter the
parameter menu. Only correct password can
make the user check or modify the parameters.
Please remember all users’ passwords.
Retreat editing state of the function codes and
the password protection will become valid in 1
minute. If the password is available, press
PRG/ESC to enter into the editing state of the
function codes, and then “0.0.0.0.0” will be
displayed. Unless input right password, the
operator can not enter into it.
Note: Restoring to the default value can clear
the password, please use it with caution.
0:No operation
1:Upload the local function parameter to the
keypad
2:Download the keypad function parameter to
local address(including the motor parameters)
3:Download the keypad function parameter to
local address (excluding the motor parameter
of P02 and P12 group)
4:Download the keypad function parameters to
local address (only for the motor parameter of
P02 and P12 group)
Note: After finish 1~4, the parameter will
restore to 0 and the uploading and
downloading does not include P29.
0x00~0x27
Ones:QUICK/JOG key function
0:Null
1:Jogging
2:Switch display state via shift key
3:Switch between FWD/REV rotation
4:Clear UP/DOWN setting
5:Coast to stop
6:Switch running command ref. mode in order
7:Quick commission mode (based on
non-default parameter)
tens:
0:keys unlocked
1:Lock all keys
2:Lock part of the keys (lock PRG/ESC key
only)
When P07.02=6, set the shifting sequence of