S I G N A T U R E
28
High salt level Low salt level
WATER LEVEL IN CELL/FLOW DETECTOR (GAS)
If an air or gas bubble appears at the top of the electrolysis cell and the FLOW DETECTOR
is not submerged, the system will automatically switch off production, with the “FLOW” [12]
light blinking and “FLO” displayed on the system information screen [11]. The system auto-
matically resets when water ows through the cell again or the bubble disappears.
WATER LEVEL WATER LEVEL
FLOW
DETECTOR
(GAS)
FLOW
DETECTOR
(GAS)
1. Submerged gas detector. System running. 2. Gas detected. System off.
EXTERNAL FLOW DETECTOR (FLOWSWITCH)
During the system conguration process (section 7.6.7), the input for the external ow switch
is activated (factory-programmed default value), the system will automatically switch off pro-
duction, with the “FLOW” [12] light blinking, and “FLO” displayed on the system information
screen [11]. The system automatically resets whenever water starts to ow through the ow
switch again.