Display Type of error You have the following
problem:
Here is how to resolve it. Intervention by
a technician
Chlorine-related errors
b04
unclear
analyses
there is an air bubble
in the analysis circuit
eliminate any air getting in yes / no
b05
unsuitable
production
there has been an external
addition of chlorine
the stabiliser content
is too high
check the constants and the
production parts (electrolyser, cell,
chlorine pump, level in the chlorine
tank, etc.) and adjust the produc-
tion settings
no
b06
low
production
problem
there is a lack of salt/The
electrode has come to the
end of its life/If you have
a chlorine pump, the liquid
chlorine may have run out
check the constants and the
production parts (electrolyser, cell,
chlorine pump, level in the chlorine
tank, etc.) and adjust the produc-
tion settings
no
b40
impossible to
get a reading.
the water contains too many
impurities
check the quality of the water
analysed
no
b41
impossible to
get a reading.
too much air is getting into
the circuit
eliminate any air getting in yes
b42
impossible to
get a reading.
either the sampling pump
or the analysis circuit is
defective
check the analysis circuit yes
b60
chlorine
reagent
there is no more reagent /
The chlorine reagent has not
been added properly
repeat the addition of the chlorine
reagent, or change it
no
b61
chlorine
reagent
the chlorine reagent tank will
soon be empty
get ready to change it / You have
not reinitialised your reagent gauge
no
b99
salt card check the amperage and
voltage in the diagnostics
menu
call a technician about this yes
pH-related errors
E04
inconsistent
analyses
there is an air bubble in the
analysis circuit
eliminate any air getting in yes / no
E05
unsuitable
production
there has been an external
addition of pH
check the pH pumps and the level
of the pH corrector tanks
no
E06
lower produc-
tion problem.
check the level of the pH+
corrector tank: it is empty or
almost empty
prepare to change it no
E07
lower produc-
tion problem.
check the level of the pH-
corrector tank: it is empty or
almost empty
prepare to change it no
E60
pH reagent there is no more reagent /
The pH reagent has not been
added properly
repeat the addition of the pH
reagent or change it
no
F61
pH reagent the pH reagent will soon be
empty
get ready to change it / You have
not reinitialised your reagent gauge
no