14
OCTOBER 24, 2008 DRAFT
OCTOBER 24, 2008 DRAFT
This table describes how the status LEDs operate.
LED Indicator Color/State Description
Power
Off No power.
Red/Steady*
Power was just applied and the MicroCell is
initializing. If it persists, a fault has occurred.
Green/Steady Power is on and there are no faults.
Ethernet
(Broadband
Connection)
Off* No connection.
Green/Steady Ethernet link.
GPS
Off Initial state.
Green/Flashing*
Searching for GPS signal (part of first-time
authentication).
Green/Steady GPS ready.
PC
(PC/Router
Connection)
Off
No connection. This is valid if you do not have a
have a PC or router, i.e., you only use the device for
MicroCell service.
Green/Steady Ethernet activity.
3G
(MicroCell
Connection)
Off No configuration and no MicroCell service.
Green/Flashing*
Initialization is in process. Flashes may be short or
medium in length.
Red/Flashing*
Fault condition(s) present that impact operation.
No MicroCell service.
Green/Steady MicroCell service available.
*If any condition marked with an asterisk persists after 30 minutes, first see Troubleshooting on
page 16 for additional information. If you are still unable to resolve the problem, contact Customer
Support at 800.331.0500 for assistance.
Device Status
3G devices registered to access AT&T 3G MicroCell™ service on your MicroCell will display this
alpha tag when service is available:
AT&T MicroCell
If you do not see this alpha tag on your device, you are either out of range of the MicroCell or
your device isn’t registered (see Approved User List), or your MicroCell is not functioning properly
(see Troubleshooting on page 16 for additional information). If you are unable to resolve the
problem, contact Customer Support at 800.331.0500 for assistance.