Line Function Setting range
or display
Setting
increment
Basic
setting
Time program heating / cooling, circuit 2
Only with the 2nd circuit kit option.
520 U Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
521 U 1st phase On (start) 00:00... --:-- 10 min 6:00
522 U 1st phase Off (end) 00:00... --:-- 10 min 22:00
523 U 2nd phase On (start) 00:00... --:-- 10 min --:--
524 U 2nd phase Off (end) 00:00... --:-- 10 min --:--
525 U 3rd phase On (start) 00:00... --:-- 10 min --:--
526 U 3rd phase Off (end) 00:00... --:-- 10 min --:--
536 U Default values, Circuit 2 No, Yes No
Yes + OK: The default values memorised in the regulator replace and cancel the customised heating programs.
Your customised settings are therefore lost.
Time program 4 / DHW
If the installation is tted with the DHW kit.
560 U Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
561 U 1st phase On (start) 00:00... --:-- 10 min 00:00
562 U 1st phase Off (end) 00:00... --:-- 10 min 05:00
563 U 2nd phase On (start) 00:00... --:-- 10 min 14:30
564 U 2nd phase Off (end) 00:00... --:-- 10 min 17:00
565 U 3rd phase On (start) 00:00... --:-- 10 min --:--
566 U 3rd phase Off (end) 00:00... --:-- 10 min --:--
576 U Default values No, Yes No
Yes + OK: The default values memorised in the regulator replace and cancel the customised heating programs.
Your customised settings are therefore lost.
Holidays, heating circuit 1 (For the Holiday program is active, the heating mode should be on AUTO).
641 U Preselection Period 1 to 8 Period 1
642 U Period Start (Day / Month) 01.01... 31.12 1
643 U Period End (Day / Month) 01.01... 31.12 1
648 U Operating level Frost protection, Reduced Frost
protection
Holidays, heating circuit 2 (For the Holiday program is active, the heating mode should be on AUTO).
If the installation consists of 2 heating circuits (Only with the 2nd circuit kit option).
651 U Preselection Period 1 to 8 Period 1
652 U Period Start (Day / Month) 01.01... 31.12 1
653 U Period End (Day / Month) 01.01... 31.12 1
658 U Operating level Frost protection, Reduced Frost
protection