EasyManua.ls Logo

Atlantic alfea extensa + - Page 56

Atlantic alfea extensa +
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Line Function Setting range
or display
Setting
increment
Basic
setting
1150 I Floor curing function (gure 1, page 54) Off
- Off: Early interruption of the current programme, programme inactive.
- Operational heating.
- Heating ready for occupation.
- Operational heating + ready heating.
- Ready heating + operational heating.
- Manual: Manual mode enables you to programme your own concrete slab drying time.The function ends
automatically after 25 days.
1151 I Floor curing setpoint manually
(if line 1150 = manual)
0... 95 °C 1 °C 25 °C
This function enables you to set the custom concrete slab drying temperature. This temperature remains xed.
The concrete slab-drying program stops automatically after running for 25 days.
1156 I Floor curing day current 0... 32
1157 I Floor curing day completed 0... 32 0
1200 S Operating mode changeover None, Protection mode,
Reduced, Comfort, Automatic
Reduced
Operating mode at end of concrete slab drying period.
Cooling circuit 2
If the installation is tted with the cooling kit (Only with the cooling kit option).
1201 U Operating mode Protection, Automatic, Reduced,
Comfort
Protection
1202 U Comfort cooling setpoint 17... 40 °C 0,5 °C 24 °C
1203 U Reduced setpoint 5... 40°C 26 °C
1208 I Flow temp setp at OT° 25°C 6... 35 °C 0,5 °C 20 °C
1209 I Flow temp setp at OT° 35°C 6... 35 °C 0,5 °C 16 °C
1212 I Cooling limit at OT° 8... 35 °C 0,5 °C 24 °C
1213 S Lock time at end of heating / cooling 8... 100 1 h 24 h
1218 S Summer comp start at OT° 20... 50 °C 1 °C 26 °C
1219 S Summer comp end at OT° 20... 50 °C 1 °C 40 °C
1220 S Summer comp setp increase 1... 10 °C 1 °C 4 °C
1223 S Flow temp setp min OT° 25°C 6... 35 °C 0,5 °C 18 °C
1224 S Flow temp setp min OT° 35°C 6... 35 °C 0,5 °C 18 °C
1228 S Room inuence 1... 100 % 1 % 80 %
If the installation is tted with a room thermostat:
This function enables you to choose the ambient temperature's inuence on the setting.
If no value is entered, the setting is made based on the temperature control.
If the parameter is set at 100%, the setting is only based on the ambient temperature.
1232 S Room temp limitation 0,5... 4 °C 0,5 °C 0,5 °C
1238 S Mixing valve decrease 0... 20 °C 1 °C 0 °C
1241 S Actuator running time 30... 873 s 1 s 240 s
1263 S With prim contr / system pump No, Yes No*
*Basic setting : 1 circuit = No ; 2 circuits = Yes.
Installation and operation manual "1734 - EN"
Heat pump air/water split 1 service alféa extensa +
- 56 -

Table of Contents

Related product manuals