EasyManuals Logo

Atlas Copco GA30C Instruction Book

Atlas Copco GA30C
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
2920 1462 00
28
Instruction book
3.7.4 Stopping
1. Press stop button (1-Fig. 3.7). LED (10) goes out. The
compressor runs unloaded for 30 seconds and then stops.
2. To stop the compressor in case of emergency, press button
(S3-Fig. 3.6). Alarm LED (8) and a pictograph representing
the button blink. After remedying the fault, unlock the
button by pulling it out and press key (4) before restarting.
3. Close air outlet valve (1- Fig. 3.6) and switch off the voltage.
4. On GA Pack FF, open condensate drain valve (1-Fig. 3.2).
3.8 Taking out of operation at end of
compressor service life
At the end of the service life of the compressor, proceed as
follows:
1. Stop the compressor and close the air outlet valve.
2. Switch off the voltage and disconnect the compressor from
the mains.
3. Depressurize the compressor by opening plug (5-Fig. 3.3)
one turn and by opening valve (1-Fig. 3.2).
4. Shut off and depressurize the part of the air net which is
connected to the outlet valve. Disconnect the compressor
air outlet pipe from the air net.
5. Drain the oil and condensate circuits.
6. Disconnect the condensate piping from the condensate net.
4 Maintenance
Attention
Apply all relevant safety precautions, including those mentioned
in this book.
Before starting any maintenance or repairs:
1. For GA Workplace/Workplace FF, press stop button (1-
Fig. 3.5), wait until the compressor has stopped (approx.
30 seconds), press emergency stop button (S3-Fig. 3.4) and
switch off the voltage.
For Pack/Pack FF, press stop button (1-Fig. 3.7), wait until
the compressor has stopped (approx. 30 seconds), press
emergency stop button (S3-Fig. 3.6) and switch off the
voltage.
2. Close air outlet valve (1-Figs. 3.4/3.6) and depressurize by
opening plug (5-Fig. 3.3) one turn and by opening valve (1-
Fig. 3.2) (not provided on GA Pack).
3. The air outlet valve (1-Figs. 3.4/3.6) can be locked during
maintenance or repair as follows:
- Close the valve.
- Remove the bolt fixing the handle.
- Lift the handle and turn it until the slot of the handle fits
over the blocking edge on the valve body.
- Lock the handle using the special bolt and wrench
delivered loose with the compressor.
4.1 Drive motor (3- Fig. 3.1)
The motor bearings are greased for life
4.2 Service actions for GA Pack/Pack FF
GA Pack and Pack FF are provided with the Elektronikon I
regulator (Fig. 3.7).
Besides the daily and 3-monthly checks, the service operations
are grouped in time intervals (running hours); see section 4.4.
The regulator has a programmable service timer. When the
timer reaches the programmed interval, LED (8-Fig. 3.7) will
light up. Press key (12-Fig. 3.7), r000 appears. Press key
(5-Fig. 3.7), S (S standing for Service) appears. In this
case, check the running hours. Carry out the service operations
corresponding to the running hours as specified in the schedule
of section 4.4.
Reset the service timer after servicing. For detailed information,
consult the User manual for Elektronikon I and II regulators,
Part 1, section 6.
Important
If using mineral oil instead of Atlas Copco Roto-injectfluid,
the service timer interval has to be decreased: 500 running hours
for 13 bar (175 psi) units and 1000 running hours for 7.5-10
bar (100-150 psi) units.
4.3 Service plans for GA Workplace/
Workplace FF
GA Workplace and Workplace FF are provided with the
Elektronikon II regulator (Fig. 3.5).
Besides the daily and 3-monthly checks, the service operations
are grouped in plans, called Service plans A, B or C; see section
4.4.
Each plan has a programmed time interval at which all service
actions belonging to that plan are to be carried out.
When reaching the interval, a message will appear on the screen
indicating which Service plans are to be carried out. After
servicing, the intervals are to be reset. For detailed information,
consult the User manual for Elektronikon I and II regulators,
Part 2, sections 5, 12 and 15.
Important
Always consult Atlas Copco in case any timer setting should
be changed.

Table of Contents

Other manuals for Atlas Copco GA30C