4.2.6 Switching on/off the floodlights
4.2.6.1 Switching on the floodlights
manually
1. Make sure the mast is up and in the desired
operating position. See section 4.2.4.
2. Switch ON the 4 circuit breakers (Q2-5) (1).
3. Push the AUTO button on the Lc1003™ module
(2) to ignite the lamps.
In sequence, every 2 seconds one lamp will ignite
automatically.
4.2.6.2 Switching off the floodlights
manually
To switch the lights off manually, follow the
procedure described below and proceed to lower the
mast.
1. Push the START button on the Lc1003™ module
(1) to shut down the lamps.
2. Place the 4 automatic switches (Q2-5) (2) in their
OFF position.
4.2.6.3 Switching on/off the floodlights
automatically
1. Make sure the mast is up and in the desired
operating position. See section 4.2.4.
2. Put the starter switch S20 in position REMOTE
(1).
3. Switch ON the 4 circuit breakers (Q2-5) (2).
4. Push the AUTO button on the Lc1003™ module
(3) to activate AUTO mode.
The floodlights will ignite/switch off
automatically depending on the luminosity
(optional Photocell) or a set time schedule.
On light towers with Lc1001™
module the flood lights are now
ignited.
S50
S51
S20
0
1
F10
H15 S25
0 1
Q2 Q3 Q4 Q5Q1
P7
Q6
Q1 Q2 Q3 Q4 Q5 Q6 P8
ON
P7
S30
0
DOWNUP
Lc1003
2
1
When the light tower is connected to
the mains (“External power input
(230 VAC), with battery charger”
option, S10 in position 2, see section
7.4.3.) all lights will ignite at the
same time, as soon as circuit
breakers Q2-Q5 are switched ON.
On light towers with Lc1001
module the flood lights can be
switched on/off manually by
switching ON/OFF the automatic
switches (Q2-Q5).
S50
S51
S20
0
1
F10
H15 S25
0 1
Q2 Q3 Q4 Q5Q1
P7
Q6
Q1 Q2 Q3 Q4 Q5 Q6 P8
ON
P7
S30
0
DOWNUP
Lc1003
1
2
Only applicable with timer or
optional Photocell, see section 7.4.7.
When the light tower is connected to
the mains (“External power input
(230 VAC), with battery charger”
option, S10 in position 2, see section
7.4.3.) all lights will ignite at the
same time, as soon as circuit
breakers Q2-Q5 are switched ON.
S50
S51
S20
0
1
F10
H15 S25
0 1
Q2 Q3 Q4 Q5Q1
P7
Q6
Q1 Q2 Q3 Q4 Q5 Q6 P8
ON
P7
S30
0
DOWNUP
Lc1003
3
1
2
00_00_HiLight H5+-H2_EN.book Page 30 Thursday, February 27, 2020 3:23 PM

Table of Contents

Related product manuals