- 23 -
OPERATION
Starting the engine of HiLight V3+ and HiLight
V2+
1. Before starting the engine
Obey all safety instructions given in section
Engine safety
Check engine oil, fuel and coolant levels. Do
not operate the engine if the fuel tank is empty
or if fuel level is below minimum mark.
Use only petrol fuel.
Prime the engine fuel lines if the fuel tank was
empty or while using the engine for the first
time. Refer the engine manual for priming
procedure.
Make sure that the light tower circuit breakers
are set to "OFF" position.
2. Starting the engine
1. Insert the engine key in the key slot on the
engine.
2. Turn the key clockwise for one "click". This
will illuminate the glow plug.
3. Crank the engine only after the glow plug light
goes off. The glow plug stays illuminated till
the engine starter coil temperature becomes
equal to the set temperature.
4. Turn and hold the key in the "START" position
for 10 seconds.
5. Release the key when the engine starts. Release
the key if the engine does not start in 10
seconds.
6. The engine will shut down automatically if oil
pressure does not increase to set pressure in 30
seconds after starting.
3. Stopping the engine
1. Stop the power supply to the bu
lbs and
ext
ernally connected devices.
2. Turn the engine key to the off position.
4. Automatic engine shutdown
The engine has an auto-shutdown system. This
system makes the engine shut down automatically if
the oil pressure is too low or if the engine temperature
is too high. This prevents damage to engine
components.
The engine starting procedure after auto-shutdown is
as below:
1. Turn the key to "OFF" position and wait for 60
seconds.
2. Turn the key clockwise for one "click". This
will illuminate the glow plug.
3. Crank the engine only after the glow plug light
goes off. The glow plug stays illuminated till
the engine starter coil temperature becomes
equal to the set temperature.
4. Turn and hold the key in the "START" position
for 10 seconds.
5. Release the key when the engine starts. Release
the key if the engine does not start in 10
seconds.
6. The engine will shut down automatically if oil
pressure does not increase to set pressure in 30
seconds after starting.
Before starting the HiLight V2+ or
HiLight V3+, read the instruction
manual carefully.
Do not hold the key for more than 10
seconds. Release the key if the engine
does not start in 10 seconds. Do not try to
start the engine immediately. It will
cause the engine to overheat. This will
damage the starter motor. Wait for 30
seconds before starting the engine again.
Before starting the HiLight V2+ or
HiLight V3+, read the instruction
manual carefully. Obey all safety
instructions given in section Engine
safety.
Always break the electrical circuit
before stopping the engine. This
prevents damage to the LED lamps and
generator.
Do not hold the key for more than 10
seconds. Release the key if the engine
does not start in 10 seconds. Do not try to
start the engine immediately. It will
cause the engine to overheat. This will
damage the starter motor. Wait for 30
seconds before starting the engine again.
Before starting the HiLight V2+ or
HiLight V3+, read the instruction
manual carefully. Obey all safety
instructions given in section Engine
safety.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco HiLight V2+ and is the answer not in the manual?

Atlas Copco HiLight V2+ Specifications

General IconGeneral
BrandAtlas Copco
ModelHiLight V2+
CategoryLighting Equipment
LanguageEnglish

Related product manuals