- 25 -
2. Lowering
a) Lowering the mast
1. De-energize the LED lamps by disconnecting power supply or by shutting
down the engine.
2. Rotate the handle of the winch (1) till the mast reaches the lowest level.
OPERATING THE LED LAMPS
1. Energizing
the LED lamps
a) Energizing LED lamps for HiLight V3+ and HiLight V2+
1. Start the engine. Refer to section Starting the engine of HiLight V3+ and
HiLight V2+
2. Switch the circuit breaker to "ON" position. LED lamp energizes instantly.
b) Energizing LED lamp for HiLight P2+
1. Connect the light tower plug to the main power supply.
2. Switch the circuit breaker to "ON" position. LED lamp energizes instantly.
2. De-energizing the LED lamps
a) De-energizing the LED lamps for HiLight V3+ and HiLight V2+
1. Switch the circuit breaker to "OFF" position. The LED lamp de-energizes
instantly.
2. Stop the engine. Refer to section Stopping the engine.
b) De-energizing the LED lamps for HiLight P2+
1. Switch the circuit breaker to "OFF" position.
2. Disconnect the light tower plug from the main power supply.
Before moving the light tower, lower the mast and lock it in place.
This prevents injury caused by falling objects.
• The operator should prevent twisting and pinching of cables and
wires while lowering the tower mast.
• De-energize the light tower before lowering the tower. Touching
live electrical circuits can cause electric shock and can result in
injury or death.
De-energize the light tower before touching the LED lamps.
Touching live electrical circuits can cause electric shock and can
result in injury or death.
Always break the electrical circuit before stopping the engine. This
prevents damage to the LED lamps and generator.