EasyManuals Logo

Atlas Copco HiLight V2+ User Manual

Atlas Copco HiLight V2+
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
- 26 -
MAINTENANCE
REGULAR INSPECTION
Do the following inspection regularly:
Check for fuel leakage. Identify the source of leakage.
Examine the exposed wires for wear, damage or cuts.
Examine the winch cable for wear or damage.
REPLACING THE LAMP
The LED lamp has an average life of 50,000 running hours. The LED should be
replaced only if it does not get energized after service from a certified technician.
1. Replacing the lamp for HiLight V3+
a) Remove the 6 screws (1) using a pneumatic tool.
b) Remove the LED protective cover (2).
c) Disconnect the LED power lines.
d) Replace the LED.
e) Re-connect the power lines to the LED.
f) Fit the LED protective cover (2) to the lamp using the 6 screws (1).
Do all maintenance activities when the light tower is de-energized.
Touching live electrical circuits can cause electric shock and can
result in injury or death.
Never use the light tower if components are damaged. It can cause
an accident which can result in injury or death.
Lamps will last longer if used carefully.