Controller
9836 3123 01 139 (428)
Besides the 'default configuration' and 'totally configurable' (which gives the
possibility to manually configure the Power Focus memory freely), Power Focus provides seven
more configurable memory options; More Psets, More Jobs, More Results, More Events, More Identifiers,
QDAS, and Pset comments.
Selection
Psets
Jobs
Results
Events
Identifiers
Statistical
events
Identifier
result parts
Traces
Default configuration
250
99
5000
100
100
100
1
8
More Psets
300
100
4000
100
100
100
1
8
More Jobs
100
400
4000
100
100
100
1
8
More results
100
100
6000
100
100
100
1
8
More events
200
100
5000
500
100
100
1
8
More identifiers
200
100
5000
100
400
100
1
8
Totally configurable
1-600
1-700
1-9000
1-800
400
1-500
1-4
1-100
QDAS
250
99
4000
100
100
100
1
8
Pset comments
200
100
5000
100
100
100
1
8
Number of identifiers is the maximum number of significant identifier strings available for identifier Type 1
(Identifier Type 1 is used to trigger Psets, Multistages or Jobs). Number of identifier result parts is the
amount of Identifier strings to be stored together with the tightening result. For more information, see
section Identifier.
When increasing database elements, a decreasing of other elements might be necessary. For instance, if
6000 results are required it is not possible to have more than 100 Psets (option more results).
Memory setup
Store existing data, see Store PF to file, including Psets, Multistages, and Jobs before changing the
memory setup. The data can later be retrieved, see Read PF from file.