EasyManua.ls Logo

Atlas Copco Power Focus 4000

Atlas Copco Power Focus 4000
428 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Event codes
9836 3123 01 401 (428)
Event
code
Event name
Description
Procedure
Acknowledge
PF ready
Tool ready
E286
Reset Identifier
not possible
Reset latest identifier is not possible when
a complete Work Order has been
accepted.
Use digital input Reset all identifiers.
E287
All Result Parts
can not be stored
All Result Parts can not be stored.
Make sure that the Job Master and all
of the Job Members have the same
number of Result Parts in the
configuration.
Make sure that the Sync Master and
all of the Sync Members have the
same number of Result Parts in the
configuration.
23.1.4 E300-E399 Statistical events
Event
code
Event name
Description
Procedure
E333
Not allowed
subscription
The requested statistic subscription is not allowed. For
example it is not allowed to set an angle statistic
subscription for a Pset using only the torque control
strategy.
Change the subscription.
E334
No statistic available
for this Pset
The Pset strategy is not suitable to calculate statistics (no
strategy is chosen).
For information only.
E335
Not enough data
Not enough data is available to calculate the statistic
control limits.
Do more tightenings to get
enough data.
Calculation used: nbrofsubgroups
* subgroupsize * (1 + subgroup
frequency)
Check and if necessary change
P503 No of subgroups.
E336
Mem alloc fail
It is not possible to allocate enough memory for the
statistic subscription.
Open Controller > Memory and
set C600 Type to Totally
configurable.
Check settings.