Connecting devices
9836 3123 01 37 (428)
Pin
Function
13
Digital input 1 +
14
Digital input 1 -
15
Digital input 2 +
16
Digital input 2 -
17
Digital input 3 +
18
Digital input 3 -
19
Digital input 4 +
20
Digital input 4 -
21
+ 24 VDC isolated
22
GND (+24VDC isolated)
4.8 Digital outputs (relays)
Connector: 12-pin detachable screw terminal. Mating connector phoenix MCVR 1.5/12-ST-3.81 or
compatible.
Function: Two ways dry contact relays, isolated outputs. Logical function is set in the configuration of the
Power Focus.
Electrical data: Max 50 V DC/AC. Switching load: min 1 mA, max 500 mA resistive loads.