Tool
150 (428) 9836 3123 01
Button pressed
Button released
Push detection interval
Next push interval
Time
Timeout
Single push
Single push - the button is pressed down and released before the T236 Push detection interval expires. The
T237 Next push interval expires before the button is pressed again.
Button pressed
Button released
Next push interval
Time
Button pressed
Button released
Push detection interval
Double push
Push detection interval
Double push - the button is pressed down and released before the T236 Push detection interval expires.
Then the button is pressed down before the T237 Next push interval expires and is released before the T236
Push detection interval expires.
Button pressed
Button released
Push detection interval
Time
Pressed
Timeout
Released
Pressed - the button is pressed down and is kept down for a longer time than the T236 Push detection
interval. When the Push detection interval expires, the button function is considered to be pressed until it is
released. Notice that if no function is configured for single push or double push in the current tool
direction, the Push detection interval is ignored and the button function is considered to be pressed as soon
as it is pressed down.
It is possible to configure a digital input function, similar to the digital inputs on PF, for each user
interaction type and tool direction. Tool direction is shown by the direction ring on ST tools and by the
direction LED on SL tools.