Single push - the button is pressed down and released before the T236 Push detection interval expires. The
T237 Next push interval expires before the button is pressed again.
Double push - the button is pressed down and released before the T236 Push detection interval expires.
Then the button is pressed down before the T237 Next push interval expires and is released before the T236
Push detection interval expires.
Pressed - the button is pressed down and is kept down for a longer time than the T236 Push detection
interval. When the Push detection interval expires, the button function is considered to be pressed until it is
released. Notice that if no function is configured for single push or double push in the current tool
direction, the Push detection interval is ignored and the button function is considered to be pressed as soon
as it is pressed down.
It is possible to configure a digital input function, similar to the digital inputs on PF, for each user
interaction type and tool direction. Tool direction is shown by the direction ring on ST tools and by the
direction LED on SL tools.