Fieldbus
224 (428) 9836 3123 01
InterBus module
Variable
Limits
Node Address
Auto select
Number of nodes in an InterBus network
Baud rate
500 Kbit/sec, 2Mbit/sec
Process string length
<= 20 bytes
Parameter string length (send with PCP)
200 byte Process string length
The string length in the Power Focus is limited to 200 bytes. InterBus standard
allows 512 bytes.
PCP length
0, 1, 2, 4 Words
Parameter data index
0x6000 R/W + I (I = 0, 1, …)
0x6040 RO + I (I = 0, 1, …)
ID code (in PLC side)
PCP 0 = 3
PCP 1 = 0xF3
PCP 2 = 0xF0
PCP 4 = 0xF1