A subgroup is a group of tightenings. Subgroup size is freely programmable and in the example above it is
set to 5, which means that all values in the same group range from i to i+4.
X-bar is the calculated average of the last completed subgroup.
Subgroup size = Group size = z
],,,,,min[],,,,,max[
],,,,,min[],,,,,max[
2212211
1121
zizizizizizin
ziiiziiin
XXXXXXW
XXXXXXWGrouprange
6
5
n
nj
j
W
W
W
ll
CAM
*6
)min(max746.1
The formula for CAM is calculated using the first 6 subgroups. After that, a new calculation is made using
each completed subgroup in conjunction with the last 6 subgroups.
n
i
i
x
n
X
1
1
n
i
i
r
n
R
1
1
XUCL X A R
2
XLCL X A R
2
RUCL D R
4
RLCL D R
3