Event codes 
392 (428)  9836 3123 01 
Tool locked by 
Tools Talk 
The tool is prohibited via ToolsTalk PF. 
 
Additional parameter information:  
First integer parameter: 0=locked during 
tightening, 1=locked during loosening, 
2=locked during positioning, 3=locked 
during motor tuning, 4=locked during 
open end tuning. 
Second integer parameter 0=Service 
denied, 1=service aborted. 
Unlock the tool by  
- sending an “Enable tool” message via 
ToolsTalk PF protocol or 
- using digital input Master unlock 
tool. 
This event code is displayed if the tool is 
locked by the function P152 Lock at batch 
OK.  
Additional parameter information:  
First integer parameter: 0=locked during 
tightening, 1=locked during loosening, 
2=locked during positioning, 3=locked 
during motor tuning, 4=locked during 
open end tuning. 
Second integer parameter 0=Service 
denied, 1=service aborted. 
Unlock the tool by  
- using the digital inputs Unlock tool 
or Master unlock tool or  
- sending an “Enable tool” message on 
fieldbus, Open protocol or ToolsTalk 
PF protocol. 
The tool is locked by fieldbus.  
Additional parameter information:  
First integer parameter: 0=locked during 
tightening, 1=locked during loosening, 
2=locked during positioning, 3=locked 
during motor tuning, 4=locked during 
open end tuning. 
Second integer parameter 0=Service 
denied, 1=service aborted. 
Unlock the tool by  
- sending an “Enable tool” message via 
fieldbus or  
- using the digital input Master unlock 
tool. 
Wrong tool start 
input source 
It is only possible to start the tool from 
selected tool start select source.  
Check the setting for T200 Tool start 
select source.  
Tool locked by 
Open protocol 
The tool is locked by open protocol.  
Additional parameter information:  
First integer parameter: 0=locked during 
tightening, 1=locked during loosening, 
2=locked during positioning, 3=locked 
during motor tuning, 4=locked during 
open end tuning. 
Second integer parameter 0=Service 
denied, 1=service aborted. 
Unlock the tool by  
- sending an “Enable tool” message via 
Open protocol or  
- using the digital input Master unlock 
tool.