Event codes
396 (428) 9836 3123 01
Event
code
Event name
Description
Procedure
Acknowledge
PF ready
Tool ready
E166
Job aborted
This event will be displayed when a
running Job is aborted.
Additional parameter information.
First integer parameter:
2
Digital input
3
Ethernet/serial (PC
5
Field bus
6
Keyboard
7
Reserved
8
Reserved
9
Manual mode (the current active
job is aborted and a new job
becomes active when selected from
digital input)
10
Timer 1 (max time to start job)
11
Timer 2 (max time to complete job)
12
Deleted (a pending job is deleted
from PF database)
13
Job off mode
14
Line control
Alarm 2
15
Job override
For information only.
E167
Max coherent Not
OK tightenings
reached
When the number of NOT OK tightenings
in a row is reached, then the tool will be
locked and can be unlocked only via a
digital input (reset NOK counter).
For information only.
x
E168
ST scanner
settings not
production default
Issued at ST scanner power-on if scan
engine settings are not the same as
production defaults.
For information only.
E169
ST scanner
settings not at
highest security
level
Issued at ST scanner power-on if scan
engine settings are not at the highest
security level.
For information only.
E175
Configuration will
be erased at next
reboot
The Power Focus will erase the
configuration in the Power Focus memory
and the RBU since the memory setup has
been changed.
Accept or reject the memory re-
configuration.
E177
Functionality not
in RBU
The user is trying to use functionality that
is not enabled in the RBU.
Replace the RBU or use another
functionality.