Event codes
410 (428) 9836 3123 01
Event
code
Event name
Description
Procedure
Acknowledge
PF ready
Tool ready
E501
Tool overheated
The tool is too hot and the drive is
disabled.
Additional parameter information:
First integer parameter indicates at which
stage the tool was locked:
0=Tightening, 1=Loosening,
2=Positioning, 3=Motor tuning, 4=open-
end tuning,
Second integer parameter: 0=Service
denied, 1=service aborted.
Let the tool rest until it is cool enough
to run.
If the event reappears, reconsider the
workstation set-up and the tightening
strategy.
Service the tool.
x
x
E502
Tool service
interval expired
Service the tool. See parameter T413
Service interval.
Additional information:
The event appears, for 3 seconds, every
100 tightenings after T412 No of
tightenings since service exceeds T413
Service interval, and T411 Service indicator
= ON. The alarm LED indicates tracking
during this period.
The tool is locked if T416 Lock tool on
alarm is checked.
Acknowledge the event.
Service the tool.
Open Tool > Maintenance > Service,
click Service counter reset and confirm
by clicking OK.
Note: To remove the event and unlock
the tool, set T411 Service indicator to
Off.
E503
Calibration date
expired
The calibration date has expired.
Use a torque measurement equipment
to calculate a calibration value.
Update tool calibration value using
T402 Set calibration value.
Update parameter T405 Calibration
alarm date.
E504
Tool wear
indicator alarm
Tool wear indicator alarm indicates that the
tool should be serviced.
Service the tool.
Connect tool to ToolsTalk Service and
reset the wear indicator.
E505
Tool rebuilt
to/from OE-type
Tool redesigned. E.g. angled tool type
redesigned to an OE-tool type.
For information only.
x
x
E506
Tightenings
prevented by
RBU
Tool locked due to incurred software
release and with wrong RBU.All Hea d
build requires a FieldTest RBU to be able
to perform tightenings.
Change to a RBU that supports the
used build.
x
x
E507
Motortuning
performed
A motortuning has been performed.
Measured values from the tool motortuning
process are entered in sub information
arguments 1 to 4
For information only.
x
x