Event codes
412 (428) 9836 3123 01
Tool
normalization
out of range
Tool normalization value out of range,
service tool.
Acknowledge the event.
Use a torque measurement equipment
to calculate a normalization value.
Use the strategy DS-control during
measurements.
Open Tool > Maintenance >
Calibration and update T403
Normalisation value.
Tool calibration
value out of
range
Tool calibration value out of range, service
tool.
Acknowledge the event.
Recalibrate the tool, using ACTA.
If the event reappears, replace the tool.
Wear indicator
data in tool
invalid
Data in tool memory used for wear
indicator is invalid. Service tool.
Open Tool > Maintenance > Wear
and set T434 Min wear tightenings to
<100000.
Wear data in tool
not updated
Tool memory or MC software not
responding.
Acknowledge the event.
Check that the tool cable and
connectors are undamaged and
correctly connected.
Please reboot PF
Cables to transducer cut off or shorted.
Acknowledge the event.
Check that the tool cable and
connectors are undamaged and
correctly connected.
If the event reappears, service the tool.
Cables to transducer cut off or shorted.
Check that the tool cable and
connectors are undamaged and
correctly connected.
Calibration not
OK, offset
outside limits
Calibration offset outside limits.
Calibration not
OK, CalVal
outside limits
Calibration value outside limits.
Calibration not
OK, Offset
changed > 5% of
max value since
last calibration
Calibration not OK, offset changed > 5%
of max value since last calibration.
Try to calibrate again.
If the event reappears, service the tool.