© Atlas Copco Industrial Technique AB - 9836 4954 01
Digital input connector Power Focus 4000
Pin Function
22 GND (+24VDC isolated)
21 +24VDC isolated
20 Digital input 4 -
19 Digital input 4 +
18 Digital input 3 -
17 Digital input 3 +
16 Digital input 2 -
15 Digital input 2 +
14 Digital input 1 -
13 Digital input 1 +
Digital output connector
The Power Focus has four configurable internal digital outputs (DIG OUT) that
are located behind the front access door.
Digital output connector Power Focus 600
Pin Relay Function
1 Normally closed
2 Relay 1 Common
3 Normally open
4 Normally closed
5 Relay 2 Common
6 Normally open
7 Normally closed
8 Relay 3 Common
9 Normally open
10 Normally closed
11 Relay 4 Common
12 Normally open