Power Focus 600 EN
© Atlas Copco Industrial Technique AB - 9836 4954 01
39
Scenario
A Socket selector is used since a specific tightening procedure requires a certain
socket. This can be the case in, i.e., a batch sequence where a specific batch re-
quires a certain socket to be activated for the batch being able to be run. If this
is not the case the tool will be locked.
Description
Perform system check
{ , : profile4 in element [iosection]}
Display system information about controller, tool, cable and accessories.
Reference information
Digital input connector
The Power Focus has four configurable internal digital inputs (DIG IN) that are
located behind the front access door.
Digital input connector Power Focus 600
Pin Function
13 24V
14 24V
15 0V
16 0V
17 0V
18 Digital input -
19 Digital input 1 +
20 Digital input 2 +
21 Digital input 3 +