- 107 -
Note: see table
(O)
Cubicle
Eberspächer preheater (O)
Connect to
starter motor (+)
PH-24
13
X9
12
X9
14
X9
M2
M
PH-19
R10
S2c
PH-24M
PH-19
PH-19
PH-3
PH-2
PH-4
Hydronic
2
4
3
7
1
N2
15A
F11
Connect to
starter motor GND
PH-19
PH-1
24M
Timer
N1
2
3
1
a3
172
b3
171
K8
a3
172
C5
C5
PE
PE
b3
171
c6
12
aa0
CL
aa9
CH
c2
1
C4
C4
B1
B1
A1
A1
X10
B2
B2
C2
C2
a3
172
10
l0
1
l0
c2
1
b3
171
12
l0
12
l0
aa9
CH
aa0
CL
c6
12
S1
M1
87654321
CANBUS
M
-
+
G1
-
+
1
l0
a2
17
A5
A5
X10
a6
12
+
-
2
B7
4
3
a3
11
b6
12
Canopy
Cubicle
C1
C1
A
B
C
D
EFG H
Wire size :
Colour code :
54= green/yellow
1 = brown
0 = black
2 = red
3 = orange
4 = yellow
5 = green
6 = blue
7 = purple
8 = grey
9 = white
l = 95 mm²
aa = 0.5 mm²
a = 1 mm²
b = 1.5 mm²
c = 2.5 mm²
d = 4 mm²
e = 6 mm²
f = 10 mm²
g = 16 mm²
h = 25 mm²
i = 35 mm²
bx = 150 mm²
k = 70 mm²
j = 50 mm²
connected
connected
QAS600
QAS500
Unit
not connected
not connected
not connected
connected
connected
Cubicle pin C5
QAS125
QAS150
QAS200
QAS325
QAS275
d2
d2
K8
a8
K7
Position of Relay Cont.
Canopy
Cubicle

Table of Contents